Common commissioning and acceptance-test scenarios for data center, UPS, generator, CDU and microgrid projects.
Validate PDU, UPS, generator, switchgear and cooling capacity before IT equipment is installed.
Apply controlled heat load to check flow, pressure, Delta T, alarm response and report data.
Test backup power transfer, discharge behavior, bypass operation and step-load response.
Simulate AC/DC load profiles for inverter, battery storage and hybrid power validation.
Common commissioning and acceptance-test scenarios for data center, UPS, generator, CDU and microgrid projects.
High-density reactive load simulation up to 5000kVA
Modular design for flexible capacity configurations
Remote monitoring and test report export
Validate your microgrid's performance with our advanced renewable energy load testing systems. Whether integrating solar, wind, or energy storage, our load banks deliver precise testing for grid-tie inverters, battery systems, and hybrid power configurations.
AC/DC combined loading for hybrid system testing
Dynamic load profiling for renewable integration
Standalone and grid-connected operation modes
Remote monitoring and test report export
Compare Batterlution load bank categories by capacity range, cooling method, application and buyer fit before requesting a quotation.
Product Category |
Typical kW Range |
Cooling Method |
Typical Application |
Best For |
|---|---|---|---|---|
|
Liquid-Cooled Load Bank |
100 kW-5 MW |
Liquid-cooled |
Data center load bank testing, CDU and cooling loop validation |
Data center owners, commissioning teams, cooling integrators |
|
Rack-Mounted Load Bank |
10 kW-100 kW per rack |
Air-cooled or liquid-cooled |
IT rack load simulation, rack PDU and server room testing |
Data center operators and rack-level commissioning teams |
|
Dual-Source Load Bank |
Project-based |
Air-cooled or liquid-cooled |
UPS failover, A/B power path and generator-backed redundancy tests |
Critical power engineers and facility acceptance teams |
|
Containerized Load Bank |
500 kW-5 MW |
Forced air or project-specific |
Generator validation, grid testing and outdoor high-power load testing |
EPC contractors, generator rental teams and utilities |
|
Regenerative Battery Tester |
Project-based DC power |
Power-electronics based |
Battery discharge, energy recovery and DC microgrid testing |
Battery labs, ESS manufacturers and microgrid developers |
High-capacity liquid-cooled load banks designed to simulate both data center IT loads and liquid cooling systems, enabling comprehensive cooling infrastructure validation.
Range: 100 kW-5 MW
Use: Data center load bank testing and CDU validation
Standard 19-inch rack-mountable design that integrates seamlessly into server racks, accurately simulating real-world data center workloads.
Range: 10 kW-100 kW per rack
Use: Rack-level load bank testing before server installation
Dual-input load banks with mechanical interlock, ensuring either Source A or Source B is active to validate failover and redundancy systems.
Range: Project-based AC capacity
Use: UPS failover and A/B power path validation
High-capacity liquid-cooled load banks designed to simulate both data center IT loads and liquid cooling systems, enabling comprehensive cooling infrastructure validation.
Range: 100 kW-5 MW
Use: Data center load bank testing and CDU validation
19-inch rack-mount design with liquid cooling simulation, specifically engineered to test CDU (Coolant Distribution Units) and liquid-cooled server configurations.
Range: Rack-level liquid-cooled capacity
Use: CDU testing load bank and liquid-cooled server simulation
Energy-regenerative systems that return power to the grid, reducing operational costs and environmental impact.
Range: Project-based DC power
Use: Battery discharge, ESS and regenerative DC testing
Intelligent control system for comprehensive monitoring and seamless load testing operations
Dual control via local touchscreen and remote PC, allowing for seamless operation both on-site and off-site.
Dual control via local touchscreen and remote PC, allowing for seamless operation both on-site and off-site.
Supports report generation in PDF, CSV, and Excel formats.
Features automated load shedding and instant notifications in the event of overvoltage, overcurrent, overheating, or fan failure.
Batterlution builds around real project inputs: required kW, voltage, cooling method, site layout, control interface, test duration and documentation requirements.
10kW ~ 5MW
AC208V ~ 13.8kV / DC24V ~ 1500V
Air-Cooled / Liquid-Cooled / Hybrid
50Hz / 60Hz / 400Hz
Capacity, voltage, frequency and load step resolution are configured around the test plan.
Local operation, automatic sequences, alarm logic and test procedure control can be configured.
Support for Modbus RTU/TCP, PC software, data logging and remote supervision.
Factory acceptance records, site test reports, CSV/Excel/PDF exports and handover data.
Packaging, accessories and shipment preparation for international commissioning projects.
From R&D to final integration, our factory specializes in custom load bank solutions tailored to your specific voltage and frequency requirements.
Ready to find the perfect load testing solution? Contact our team today.