• Custom Load Banks for Data Center, UPS and Generator Testing

    Validate liquid-cooled data center power and cooling loops with controlled load, temperature, flow and report data before live IT deployment.
  • Liquid-Cooled Load Banks

    Validate liquid-cooled data center power and cooling loops with controlled load, temperature, flow and report data before live IT deployment.
  • Dual-Source Load Banks

    Test UPS failover, dual feeder paths and generator-backed redundancy with isolated load channels and repeatable switching records.

Load Bank Applications

Common commissioning and acceptance-test scenarios for data center, UPS, generator, CDU and microgrid projects.

Data Center Commissioning

Validate PDU, UPS, generator, switchgear and cooling capacity before IT equipment is installed.

CDU Testing

Apply controlled heat load to check flow, pressure, Delta T, alarm response and report data.

UPS Load Testing

Test backup power transfer, discharge behavior, bypass operation and step-load response.

Microgrid Testing

Simulate AC/DC load profiles for inverter, battery storage and hybrid power validation.

Data Center Commissioning

Common commissioning and acceptance-test scenarios for data center, UPS, generator, CDU and microgrid projects.

  • High-density reactive load simulation up to 5000kVA

  • Modular design for flexible capacity configurations

  • Remote monitoring and test report export

Microgrid

Validate your microgrid's performance with our advanced renewable energy load testing systems. Whether integrating solar, wind, or energy storage, our load banks deliver precise testing for grid-tie inverters, battery systems, and hybrid power configurations.

  • AC/DC combined loading for hybrid system testing

  • Dynamic load profiling for renewable integration

  • Standalone and grid-connected operation modes

  • Remote monitoring and test report export

Industrial Load Bank Products

Compare Batterlution load bank categories by capacity range, cooling method, application and buyer fit before requesting a quotation.

Product Category

Typical kW Range

Cooling Method

Typical Application

Best For

Liquid-Cooled Load Bank

100 kW-5 MW

Liquid-cooled

Data center load bank testing, CDU and cooling loop validation

Data center owners, commissioning teams, cooling integrators

Rack-Mounted Load Bank

10 kW-100 kW per rack

Air-cooled or liquid-cooled

IT rack load simulation, rack PDU and server room testing

Data center operators and rack-level commissioning teams

Dual-Source Load Bank

Project-based

Air-cooled or liquid-cooled

UPS failover, A/B power path and generator-backed redundancy tests

Critical power engineers and facility acceptance teams

Containerized Load Bank

500 kW-5 MW

Forced air or project-specific

Generator validation, grid testing and outdoor high-power load testing

EPC contractors, generator rental teams and utilities

Regenerative Battery Tester

Project-based DC power

Power-electronics based

Battery discharge, energy recovery and DC microgrid testing

Battery labs, ESS manufacturers and microgrid developers

Hot Products

Liquid-Cooled Load Bank

High-capacity liquid-cooled load banks designed to simulate both data center IT loads and liquid cooling systems, enabling comprehensive cooling infrastructure validation.

Range:  100 kW-5 MW

Use:  Data center load bank testing and CDU validation

Rack-Mount Load Bank

Standard 19-inch rack-mountable design that integrates seamlessly into server racks, accurately simulating real-world data center workloads.

Range:  10 kW-100 kW per rack

Use:  Rack-level load bank testing before server installation

Dual-Source Load Bank

Dual-input load banks with mechanical interlock, ensuring either Source A or Source B is active to validate failover and redundancy systems.

Range:  Project-based AC capacity

Use:  UPS failover and A/B power path validation

Liquid-Cooled Load Bank



High-capacity liquid-cooled load banks designed to simulate both data center IT loads and liquid cooling systems, enabling comprehensive cooling infrastructure validation.

Range:  100 kW-5 MW

Use:  Data center load bank testing and CDU validation

Rack-Mounted Liquid-Cooled Load Bank

19-inch rack-mount design with liquid cooling simulation, specifically engineered to test CDU (Coolant Distribution Units) and liquid-cooled server configurations.

Range:  Rack-level liquid-cooled capacity

Use:  CDU testing load bank and liquid-cooled server simulation

Regenerative Battery Tester



Energy-regenerative systems that return power to the grid, reducing operational costs and environmental impact.

Range:  Project-based DC power

Use:  Battery discharge, ESS and regenerative DC testing

Software Solution

Intelligent control system for comprehensive monitoring and seamless load testing operations

Multi-Platform Synchronization

Dual control via local touchscreen and remote PC, allowing for seamless operation both on-site and off-site.

Real-Time Monitoring

Dual control via local touchscreen and remote PC, allowing for seamless operation both on-site and off-site.

Data Export

Supports report generation in PDF, CSV, and Excel formats.

Intelligent Alarm System

Features automated load shedding and instant notifications in the event of overvoltage, overcurrent, overheating, or fan failure.

Engineering Capability for Custom Load Banks

Batterlution builds around real project inputs: required kW, voltage, cooling method, site layout, control interface, test duration and documentation requirements.

Power Range

10kW ~ 5MW

Voltage Levels

AC208V ~ 13.8kV / DC24V ~ 1500V

Cooling Method

Air-Cooled / Liquid-Cooled / Hybrid

Frequency

50Hz / 60Hz / 400Hz

10 kW-5 MW Custom Design

Capacity, voltage, frequency and load step resolution are configured around the test plan.

PLC/HMI Control

Local operation, automatic sequences, alarm logic and test procedure control can be configured.

Modbus / Remote Monitoring

Support for Modbus RTU/TCP, PC software, data logging and remote supervision.

FAT/SAT Documentation

Factory acceptance records, site test reports, CSV/Excel/PDF exports and handover data.

Export Packaging

Packaging, accessories and shipment preparation for international commissioning projects.

Our Numbers

0
Years Experience
0
Projects Delivered
0
Countries Served

From Core Components to Integrated Megawatt Load Solutions

From R&D to final integration, our factory specializes in custom load bank solutions tailored to your specific voltage and frequency requirements.

Engineering Capability for Custom Load Banks

Contact Us

Ready to find the perfect load testing solution? Contact our team today.

Name: *
Company:
E Mail *
Phone:
Products Wanted:
Tell Us Details: