What are the setting modes of the Growatt SPH 10000TL3 BH-UP?
The Growatt SPH 10000TL3 BH-UP is a 3 phase hybrid solar inverter that need a high voltage battery such Ground HV (Included Ground HV2500, Ground HV 7.5k, Ground HV 10k, Ground HV 12.5k, Ground HV 15k, Ground HV 17.5k, Ground HV 20k) that can be used for a variety of applications, including self-consumption, backup power, and demand response. It has three setting modes: Load First, Battery First, and Grid First.
By Load First
In Load First mode, the inverter will prioritize powering the load, and the battery will only be used if the load requires more power than the solar panels can provide. This mode is typically used for homes or businesses that want to maximize their self-consumption of solar energy.
When the load is high, the inverter will draw power from the solar panels and the battery ( a high voltage battery such Ground HV Included Ground HV2500, Ground HV 7.5k, Ground HV 10k, Ground HV 12.5k, Ground HV 15k, Ground HV 17.5k, Ground HV 20k) to power the load. If the solar panels are not producing enough power, the inverter will draw the remaining power from the battery. The battery will be charged when the solar panels are producing more power than the load is consuming.


Battery First
In Battery First mode, the inverter will prioritize charging the battery ( a high voltage battery such Ground HV Included Ground HV2500, Ground HV 7.5k, Ground HV 10k, Ground HV 12.5k, Ground HV 15k, Ground HV 17.5k, Ground HV 20k) , and the load will only be powered if the battery has enough power. This mode is typically used for homes or businesses that want to back up their loads in case of a power outage.
When the grid power is available, the inverter will use grid power to power the load and charge the battery. If the grid power goes out, the inverter will use the battery to power the load. The battery will be charged when the grid power is restored.
Grid First
In Grid First mode, the inverter will prioritize using grid power, and the battery will only be used if the grid power goes out or is not available. This mode is typically used for homes or businesses that want to minimize their energy costs.
When the grid power is available, the inverter will use grid power to power the load. If the grid power goes out, the inverter will use the battery ( a high voltage battery such Ground HV Included Ground HV2500, Ground HV 7.5k, Ground HV 10k, Ground HV 12.5k, Ground HV 15k, Ground HV 17.5k, Ground HV 20k) to power the load. The battery will be charged when the grid power is restored.
Here are some general guidelines for choosing a setting mode:
Load First:
This mode is a good choice for homes or businesses that want to maximize their self-consumption of solar energy. However, it is important to note that this mode can drain the battery ( a high voltage battery such Ground HV Included Ground HV2500, Ground HV 7.5k, Ground HV 10k, Ground HV 12.5k, Ground HV 15k, Ground HV 17.5k, Ground HV 20k) quickly if the load is high and the solar panels are not producing enough power.
Battery First:
This mode is a good choice for homes or businesses that want to back up their loads in case of a power outage. However, it is important to note that this mode can increase your energy costs if you are using grid power to charge the battery ( a high voltage battery such Ground HV Included Ground HV2500, Ground HV 7.5k, Ground HV 10k, Ground HV 12.5k, Ground HV 15k, Ground HV 17.5k, Ground HV 20k) .
Grid First:
This mode is a good choice for homes or businesses that want to minimize their energy costs. However, it is important to note that you will not be able to use solar energy if the grid power goes out.

Conclusion
The Growatt SPH 10000TL3 BH-UP's setting modes allow you to customize the inverter's operation to meet your specific needs and goals. By carefully considering your requirements and goals, you can choose the setting mode that is right for you. Please must to be selected a correct HV battery ( a high voltage battery such Ground HV Included Ground HV2500, Ground HV 7.5k, Ground HV 10k, Ground HV 12.5k, Ground HV 15k, Ground HV 17.5k, Ground HV 20k) .